LEICA TPS1200 User Manual

Page 207

Advertising
background image

Technical Data

TPS1200

207

The index n is calculated from the formula of Barrel and Sears, and is valid for:

Formulas

If the basic value of 60 % relative humidity as used by the EDM is retained, the
maximum possible error in the calculated atmospheric correction is 2 ppm,
2 mm/km.

visible red laser

1.0002859

670

Air pressure p:

1013.25 mbar

Air temperature t:

12 °C

Relative air humidity h:

60 %

Type

Index n

carrier wave [nm]

Formula for infrared EDM

ΔD

1

Atmospheric correction [ppm]

p

Air pressure [mbar]

t

Air temperature [°C]

h

Relative humidity [%]

α

x

(7.5 * t/(237.3 + t)) + 0.7857

Formula for visible red laser

1

273.15

TPS12_051

ΔD

1

= 283.05 -

0.29196 · p

· 10

x

4.126 · 10

-4

· h

-

TPS12_052

ΔD

1

= 285.93 -

0.29493 · p

· 10

x

4.126 · 10

-4

· h

-

Advertising