Specifications

21

8.0

S

PECIFICATIONS

Table 6

Liebert PSI XR specifications

Model Number

PS1000RT3-120XR

PS1000RT3120XRW

PS1500RT3-120XR

PS1500RT3120XRW

PS2200RT3-120XR

PS2200RT3120XRW

PS3000RT3-120XR

PS3000RT3120XRW

Power Rating, VA/W

1000VA/900W

1500VA/1350W

1920VA/1920W

*

3000VA/2700W

Dimensions, W x D x H, in (mm)

Unit

17.3 x 19.3 x 3.5

(440 x 490.5 x 88)

17.3 x 19.3 x 3.5

(440 x 490.5 x 88)

17.3 x 27.6 x 3.5

(440 x 700.5 x 88)

17.3 x 27.6 x 3.5

(440 x 700.5 x 88)

Shipping

22 x 24.1 x 9

(560 x 612 x 228)

22 x 24.1 x 9

(560 x 612 x 228)

22 x 34.8 x 9.0

(560 x 884 x 228)

22.0 x 34.8 x 9

(560 x 884 x 228)

Weight, lb (kg)

Unit

56 (25)

62 (28)

92 (42)

105 (48)

Shipping

64 (29)

70 (32)

101 (46)

115 (52)

Input AC Parameters

Surge Protection

570J

Voltage Range

Without Battery Operation

83 to 159 VAC (configurable)

Frequency Range

45~65Hz, (±0.5Hz)

Input Power Cord,

10ft (3m) attached

NEMA 5-15P plug

NEMA 5-15P plug

NEMA 5-20P plug

NEMA L5-30P plug

Output Receptacles

(6) NEMA 5-15R

(6) NEMA 5-15R

(4) NEMA 5-15R

(2) NEMA 5-20R T-Slot,

accepts15A Plug

(4) NEMA 5-15R

(2) NEMA 5-20R T-Slot,

accepts15A Plug

(1) NEMA L5-30R

Voltage (Normal Mode)

110/120/127 VAC (configurable)

Voltage (Battery Mode)

110/120/127 VAC; ±5% before low-battery warning

Transfer Time

4-6 ms typical

Battery Waveform

Sinewave

Battery Parameters

Type

Valve-regulated, nonspillable, lead acid

Quantity x Voltage x Ah

4 x 12 x 7.2

4 x 12 x 9

8 x 12 x 7.2

8 x 12 x 9

Recharge Time

5 hours to 90% of rated capacity, after full discharge into resistive load

Battery Backup Time

Full Load

5 minutes

Half Load

10 minutes

Environmental

Operating Temperature, °F (°C)

32 to 104 (0 to 40)

Storage Temperature, °F (°C)

5 to 104 (-15 to 40)

Relative Humidity

0% to 90%, non-condensing

Operating Altitude

Up to 3000m (10,000 ft)

Audible Noise

<40 dBA, internal fan(s) Off; <45 dBA, internal fan(s) On

Agency

Safety

UL 1778, c-UL Listed

Emissions

FCC Part 15, Class A

Network Surge

UL 497 B

Transportation

ISTA Procedure 1A Certification

*

NEC limits the input current rating of the PS2200RT3-120XR and PS2200RT3120XRW models to 80% of the input plug's rating. Up to
2200VA/1980W is available by contacting a certified electrician to change the input plug to 30A plug. Emerson Network Power assumes no
liability for damage caused by miswiring or misapplication of the input plug.