Display board, Status board, Mode board – Lincoln Electric INVERTEC V350-PRO SVM152-A User Manual
Page 110: Troubleshooting & repair, Status board removal and replacement (continued), Procedure, F-72, F-72 figure f.30 – status board location
Advertising
V350-PRO
TROUBLESHOOTING & REPAIR
F-72
F-72
FIGURE F.30 – STATUS BOARD LOCATION
W
ARNING
REMO
TE
PO
WER
OFF
ON
A
A
MP
S
A
V
V
OL
TS
WELD
TERM
IN
ALS
SELECT
OU
TP
U
T
LINCOLN
ELECTRIC
IN
VE
RT
EC
V
35
0-P
RO
L11130-1
CS
71D
1
Display Board
L1
11
07
-2
ST
AT
US
IN
PU
T
Status Board
L1
11
10
-1
MODE SELECT
Mode Board
STATUS BOARD REMOVAL AND REPLACEMENT (continued)
PROCEDURE
1. Remove input power to the V350-PRO.
2. Using a 5/16” nut driver remove the case
wraparound cover.
3. Perform the Input Filter Capacitor
Discharge Procedure detailed earlier in this
section.
4. Locate the status board behind the front
panel of the machine. See Figure F.30.
Advertising