Display board, Status board, Mode board – Lincoln Electric INVERTEC V350-PRO SVM152-A User Manual

Page 110: Troubleshooting & repair, Status board removal and replacement (continued), Procedure, F-72, F-72 figure f.30 – status board location

Advertising
background image

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-72

F-72

FIGURE F.30 – STATUS BOARD LOCATION

W

ARNING

REMO

TE

PO

WER

OFF

ON

A

A

MP

S

A

V

V

OL

TS

WELD

TERM

IN

ALS

SELECT

OU

TP

U

T

LINCOLN

ELECTRIC

IN

VE

RT

EC

V

35

0-P

RO

L11130-1

CS

71D

1

Display Board

L1

11

07

-2

ST

AT

US

IN

PU

T

Status Board

L1

11

10

-1

MODE SELECT

Mode Board

STATUS BOARD REMOVAL AND REPLACEMENT (continued)

PROCEDURE

1. Remove input power to the V350-PRO.

2. Using a 5/16” nut driver remove the case

wraparound cover.

3. Perform the Input Filter Capacitor

Discharge Procedure detailed earlier in this
section.

4. Locate the status board behind the front

panel of the machine. See Figure F.30.

Advertising