V350-PRO

TROUBLESHOOTING & REPAIR

F-7

F-7

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.
Call 1-800-833-9353(WELD).

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTION PROBLEMS

The machine’s welding output is
very high and uncontrollable.

1. Put the Control Select in the

Local position. If the problem
is solved the remote control
device or associated circuitry
may be faulty.

1. Perform the Current

Transducer Test.

2. If the output is normal when

the Control Select is in the
Local position but the output is
very high in the Remote
position the remote board may
be faulty. Perform The SPI
Cable Resistance and Voltage
Test.

3. The control board may be

faulty.

The Weld Mode Select does not
function properly.

1. Refer to Operation Section of

this manual for normal
operation characteristics.

1. Check for loose or faulty plug

connections between the
control board and the mode
select panel. See the wiring
diagram.

2. Perform the SPI Cable

Resistance and Voltage Test.

3. The Mode Select Panel board

may be faulty.

4. The control board may be

faulty.

The Status Panel (Control and
Weld Terminals Select) does not
function properly.

1. Refer to Operation Section of

this manual for normal
operation characteristics.

1. Check for loose or faulty plug

connections between the
control board and the status
board. See the wiring diagram.

2. The Status Board may be faulty.

3. The control board may be faulty.