7. Label and remove the four leads connected to the

two wire feeder circuit breakers. Pliers may be
necessary.

8. Label and remove the two leads connecting to the

CB2 circuit breaker. Pliers may be necessary.

9. Label and remove the seven leads from the

reconnect panel. Pliers may be necessary.

10. Using a crescent wrench, remove the large plastic

nut from around the input power line located at
bottom of the rear assembly. See Figure F.41.

11. Locate the steel nut located directly on the other

side of the rear assembly behind the plastic nut
that was previously removed. See Figure F.41.

12. Using a hammer and a flathead screwdriver, firm-

ly tap the metal nut from the bottom of one of its
ribs. This tapping will loosen the nut. Note: Be
sure to tap from the bottom so the nut loosens in
a counter clockwise fashion if viewed from the
front of the machine.

13. Using a 3/8” wrench label and remove leads #202,

#203, #206, #207A from the reconnect switches.
See Figure F.41.

TROUBLESHOOTING & REPAIR

CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)

F-91

F-91

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

W

ARNING

REMO

TE

PO

WER

OFF

ON

A

AMPS

A

V

VOL

TS

WELD TERMINALS

SELECT

OUTPUT

LINCOLN

ELECTR

IC

INVER

TEC V350-PR

O

Metal Nut

Plastic Nut

#203

#207A

#206

#202

FIGURE F.41 LEAD LOCATIONS