Diagnostics panel, Diagnostics, Panel – Lenovo RD120 User Manual

Page 40

Advertising
background image

Diagnostics

panel

The

following

illustration

shows

the

controls

and

LEDs

on

the

diagnostics

panel.

DASD

NMI

PCI

PS1

SP

PS2

CNFG

MEM

CPU

FAN

VRM

OVER SPEC

TEMP

REMIND

S ERR

Light Path

Diagnostics

RAID

BRD

To

access

the

diagnostics

panel,

slide

the

release

latch

on

the

front

of

the

operator

information

panel

to

the

left.

The

following

table

lists

the

LEDs

on

the

diagnostics

panel

and

suggested

actions

to

solve

the

detected

problems.

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

LED

Description

Action

None,

but

the

system-
error

LED

is

lit.

An

error

has

occurred

and

cannot

be

diagnosed,

or

the

Advanced

System

Management

(ASM)

processor

on

the

Remote

Supervisor

Adapter

II

SlimLine

has

failed.

The

error

is

not

represented

by

a

diagnostics

LED.

Check

the

system-error

log

for

information

about

the

error.

OVER

SPEC

The

power

supplies

are

using

more

power

than

their

maximum

rating.

1.

Remove

optional

devices

from

the

server.

2.

Replace

the

failing

power

supply.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply

and

to

remove

and

install

a

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

PS

1

The

power

supply

in

bay

1

has

failed.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply

and

to

remove

and

install

a

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

1.

Make

sure

that

the

power

supply

is

correctly

seated.

2.

Replace

the

failed

power

supply.

26

ThinkServer

RD120

Types

6444,

6445,

6446,

and

6447:

User

Guide

Advertising