Removing a hot-swap power supply, Installing a fan, Removing – Lenovo RD120 User Manual

Page 82: Hot-swap, Power, Supply, Installing

Advertising
background image

Removing

a

hot-swap

power

supply

Attention:

The

information

in

this

document

regarding

installing

and

removing

power

supplies

and

connecting

and

disconnecting

power

refers

to

ac

power

supplies

only.

If

the

server

contains

dc

power

supplies,

see

the

documentation

that

comes

with

the

dc

power

supplies.

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply

and

to

install

and

remove

a

dc

power

supply.

Important:

If

the

server

has

two

power

supplies

and

you

remove

either

of

them,

the

server

will

not

have

redundant

power;

if

the

server

power

load

then

exceeds

835

W,

the

server

might

not

start

or

might

not

function

correctly.

To

remove

a

power

supply,

complete

the

following

steps:

1.

If

only

one

power

supply

is

installed,

turn

off

the

server

and

peripheral

devices.

2.

Disconnect

the

power

cord

from

the

power

supply

that

you

are

removing.

3.

Grasp

the

power-supply

handle.

4.

Press

the

orange

release

latch

down

and

hold

it

down.

5.

Pull

the

power

supply

part

of

the

way

out

of

the

bay.

6.

Release

the

release

latch;

then,

support

the

power

supply

and

pull

it

the

rest

of

the

way

out

of

the

bay.

If

you

have

other

optional

devices

to

install

or

remove,

do

so

now.

Otherwise,

go

to

“Completing

the

installation”

on

page

74.

Installing

a

fan

For

proper

cooling,

the

server

requires

that

five

fans

be

installed

for

each

power

supply

installed.

The

server

comes

with

five

replaceable

fans.

If

you

install

a

second

power

supply,

you

must

install

the

set

of

five

fans

that

come

with

the

power-supply.

Important:

Only

the

configurations

that

are

shown

in

the

following

table

are

supported.

The

fan

numbers

are

printed

on

the

microprocessor

air

baffle.

Installed

power

supplies

Required

fans

Power

supply

1

Fans

in

locations

3,

4,

8,

9,

and

10

Power

supplies

1

and

2

All

10

fans

Attention:

To

ensure

proper

server

operation,

if

a

fan

fails,

replace

it

as

soon

as

possible.

68

ThinkServer

RD120

Types

6444,

6445,

6446,

and

6447:

User

Guide