Warning int’l (ce) – Lincoln Series 1100 User Manual

Page 11

Advertising
background image

Impinger II – Digital Advantage Ops Manual –Dom & Int’l

11

ELECTRICAL INSTALLATION

When installed, the appliance must be electrically grounded and its installation must comply with the National

Electric Code, ANSI-NFPA 70, latest version, the Manufacturers’ Installation Instructions, and applicable local

municipal building codes.

IN CANADA: All electrical connections are to be made in accordance with CSA C22.2 latest version - Canadian

Electrical Code and/or Local Codes.

ALL OTHER COUNTRIES: Local gas and/or electrical codes will prevail.

1. Strain Relief is provided with each oven. International Dealer/Distributors provide applicable power

cord/plug for each customer.

2. All pole disconnection switch 3 mm open contact distance.

3. To prevent electrical shock an equal potential bonding ground lug is provided in the back. This allows

the oven to be connected to an external bonding system.

4. If used as double or triple stack and each oven has its own disconnection switch, all switches should be

close together.

RESTRAINT REQUIREMENT – Gas Oven(s) on Casters

1. The installation shall be made with a gas connector that complies with the local codes for Connectors for

Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 latest version, and a quick-disconnect device that complies

with local codes for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41 • CSA 6.9 latest version.

2. The installation of the restraint must limit the movement of the oven(s) without depending on the connector, the

quick disconnect device or its associated piping to limit the oven movement.

3. If the restraint must be disconnected during maintenance or cleaning, it must be reconnected after the oven has

been returned to its originally installed position.

OPERATIONS

1. Screw end B (lifting eye) of cable assembly to hole A. Use ¼ inch eye.

2. Screw end C (eye bolt) of cable assembly to stud in wall (D) or floor anchor (E).

NOTE: Installation point is the same for a single, double, or triple-stack oven.

WARNING

INT’L (CE):

!

This appliance must be properly grounded at time of installation. Failure to ensure

that this equipment is properly grounded can result in electrocution, dismemberment

or fatal injury.

Advertising