H high speed pulse output configuration, Lhigh speed pulse rate – Laser beta lasermike LS8000-3 User Manual
Page 144

LaserSpeed 8000-3 Instruction Handbook
RS-232/RS-422 Communication
Part No. 93463 / Drawing No. 0921-01561
Page 144 of 221
Revision A (Sep 2007)
The output will clear when the length reaches 200ft, and the Index Pulse triggers. See the
Index Pulse & Length Thresholds
section for timing details.
$H
High Speed Pulse Output Configuration
$H<CR>
Read
Response
Format:
<N>
$H<N><CR>
Set
<N>
is an integer that specifies the function of the High Speed Pulse Output. The various
outputs were described previously in the Index Pulse Output Function description.
Pulse Output Function
Value
Phase A
Phase B
0
Default (High Speed Pulse Outputs)
1
System Ready
Material Present
2 System
Ready Valid
3
System Ready
QF Pulse Output
4
System Ready
QF Warning Output
5
System Ready
Shutter Open
6
System Ready
Laser On
7
System Ready
Thermostat Output
8 Valid
Thermostat
Output
9
Pulse Phase A
Sync Output
Note: Some of the above outputs were previously described under the Index Pulse Output
Function setting.
Sync Output
Gauge-Gauge Synchronization Output that can be connected between multiple gauges in
order to synchronize measurements. See the
Gauge-Gauge Synchronization
section for
details.
L
High Speed Pulse Rate
L<CR>
Read
Response
Format:
<N>
L<N><CR>
Set