Impinger I -–1000 Series Service Manual - Domestic

29

Conveyor Control(Stepper)

Transformer

Check for 120 VAC supply to primary of

transformer, if voltage is not present, trace wiring

back to the fuse-holder. If voltage is present, check

for output voltage from the transformer secondary.

NOTE: this control transformer outputs (2)

secondary voltages. Red Leads 29 VAC Brown

Leads 10 VAC If BOTH secondary voltages are not

present, replace the transformer.

Speed Adjustment

Potentiometer

This is a 0 to 50k ohm,10 turn potentiometer. WITH

POWER OFF: remove the 3 pin potentiometer

cable plug from the motor control board. With a

digital multimeter, check the ohm reading across

the red lead to the black lead, this reading should

be 50k ohms ± 5% as the potentiometer is rotated

through its 10 turn rotation. Place the meter leads

on the red lead and white lead. Rotating the

potentiometer slowly, from low to high, the meter

should show an even transition from 0 to 50K ohms

± 5% through the 10 turn rotation of the

potentiometer. There should be no dead or open

spots through the 10 turns of the potentiometer.

Check all three leads to ground. There should be

no continuity to ground. If any of the above checks

fail, replace the potentiometer.

Conveyor Motor(Stepper)

Control

NOTE: if the conveyor drive motor becomes

jammed or begins to run at an uncontrolled speed,

the conveyor motor will stop running. To reset, turn

off the conveyor switch, wait 10 seconds, turn the

conveyor switch on. If the motor does not run after

attempting re-set, check for 2-29 VAC across the

motor terminals 1 to 2 and 3 to 5 on the conveyor

motor control. If voltage is not present at both sets

of terminals, replace control

Conveyor Drive (Stepper)

Motor

Check the drive sprocket on motor out-put shaft to

insure that it is tight.. Check motor windings –

measurements should be approximately 2 ohms.

Terminal 1-5, 2-6, 3-7, 4-8 WITH POWER OFF:

Turn the motor shaft to check for jammed gear box.

If motor shaft will not turn, replace conveyor

drive(stepper) motor.

Time/Temp Display

12.6 VAC Power Supply

Measure the transformer primary inoperative for a

nominal 120 VAC input. Measure the secondary

voltage output which will be 12.5 to 15 VAC

normally. Recheck secondary output at rear of

Time/Temp Display. Terminals 1 to 3 should read

12.5 to 15 VAC. Terminals 1 to 2 and 2 to 3 should

be exactly 1/2 of the reading across 1 to 3. If you

do not get the above secondary readings, replace

the transformer. If 120 VAC primary voltage is not

available, refer to the schematic and trace circuit

for incoming power failure. There is a 4 amp fuse in

each red secondary lead. These may be jumpered

(for test only) to determine if they are defective or

intermittent.

NOTE:

(Dual Belt Ovens)

Dual belt ovens utilize a double pole double throw

switch, which allows either of the optical encoders

to be read from a single Time/Temp. Display.

Check switch and replace as needed.