Impinger I -–1000 Series Service Manual - Domestic

45

PLACE DIGITAL VOLTMETER LEADS ON terminal S1 and S2, adjust the max pot. for a

reading of 3.4 VDC.

Place METER LEADS on terminals A1 and A2. Adjust the reg. pot. for a reading of 125 VDC.

NOTE:

In some instances when the input AC voltage runs on the high side of the normal

input range, you may have difficulty adjusting the max. pot. for a reading of 3.4 VDC. In this

instance, a reading of 3.45 VDC is acceptable.

Adjust speed pot to obtain the proper time setting for the conveyor to meet customers desired

speed .

Check conveyor travel in a no load situation to insure conveyor belt is traveling at a constant

speed.

GND
S 3
S 2
S 1
A 2
A 1
F 2
F 1
L 2
L 1

3 A.
FUSE

D. C. CONTROL BOARD "BODINE" S/N 100-4389

REG

MIN

MAX

D. C. CONTROL BOARD "BODINE" S/N 100 4389
( TOP VIEW )

3 A. FUSE

TERMINAL
STRIP