Lincoln Impringer Conveyor Oven 1000 User Manual

Page 31

Advertising
background image

Impinger I -–1000 Series Service Manual - Domestic

31

Conveyor Drive (Stepper)

Control

Perform all checks as in the above evaluation. If

the time check is okay, refer to the next section.

Check to see if the conveyor drive (stepper) motor

is running. If motor is not running, refer to

"Conveyor will not run" on page 28.

Magnet

Check to insure that the magnet (cemented to shaft

of conveyor drive (stepper) motor) has not been

damaged, or come loose from motor shaft.

Replace as needed.

Hall Effect Sensor

Check for any physical damage to Hall Effect

sensor (mounted on conveyor drive(stepper)

motor). Check all wiring and connections for

damage.

Time Display

inaccurate, erratic, or

inoperative(S/N

Q19078 & Above1000

Series) (S/N Q14791 &

Above1200 Series)

Conveyor Drive (Stepper)

Control

Check all connections for tightness or proper

location and check all wiring for visible damage.

Replace as needed. If there is still no time display,

wire in (temporarily) a new conveyor drive control.

If there is still no time display, reconnect original

conveyor drive control. Replace Hall Effect Sensor.