Piping Length And Elevation

• Capacity is based on standard length and maximum allowance length is on the basis of reliability.
• Oil trap should be installed every 5~7meters (16.4~23.0ft).

Pipe Size

Capacity

(Btu/h)

Suction

Evap

Max.

length

A

m(ft)

Additional Refrigerant

g/m(oz/ft)

Max.

Elevation

B

m(ft)

Standard

Length

m(ft)

In case more than 5m(16.4ft)

Outdoor unit

Indoor unit

A

B

A

Oil trap

Outdoor unit

Indoor unit

B

9k(C/O)

3/8"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

9k(H/P), 12k

1/2"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

18k(C/O)

1/2"

1/4"

7.5(25)

15(49)

30(98)

20(0.22)

18k(H/P), 24k

5/8"

1/4"

7.5(25)

15(49)

30(98)

30(0.32)