Operator panel service check, Operator panel ser – Lexmark 4076-0XX User Manual

Page 25

Advertising
background image

4076-0XX

Diagnostic Information

13

Operator Panel Service Check

FRU OR PROCEDURE

ACTION

1

Power Supply

Disconnect J11 from the system
board and check the following volt-
ages on the power supply cable:

J11-1 to GND = +5V dc
J11-3 to GND = +24V dc

If you do not have correct voltage,
replace the power supply. Be sure to
unplug the machine before you recon-
nect the power supply to the system
board.

2

System Board

Turn the printer on. Check for +5 V dc
at test point CE/TP near the operator
panel connector on the system board

3

Operator Panel Cover

The operator panel cover actuates
the operator panel sensor on the
operator panel. Check the cover for
any broken parts. Check the operator
panel sensor for dirt.

4

Operator Panel Card
Operator Panel Cable

Check the operator panel cable for
continuity. If the cable is good,
replace the operator panel. If the
symptom remains, replace the sys-
tem board.

Advertising