Hard disk drive problems, Intermittent problems, Hard – Lenovo 3797 User Manual

Page 147: Disk, Drive, Problems, Intermittent

Advertising
background image

Hard

disk

drive

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

Not

all

drives

are

recognized

by

the

hard

disk

drive

diagnostic

test

(the

Fixed

Disk

test).

Remove

the

drive

that

is

indicated

by

the

diagnostic

tests;

then,

run

the

hard

disk

drive

diagnostic

test

again.

If

the

remaining

drives

are

recognized,

replace

the

drive

that

you

removed

with

a

new

one.

The

server

stops

responding

during

the

hard

disk

drive

diagnostic

test.

Remove

the

hard

disk

drive

that

was

being

tested

when

the

server

stopped

responding,

and

run

the

diagnostic

test

again.

If

the

hard

disk

drive

diagnostic

test

runs

successfully,

replace

the

drive

that

you

removed

with

a

new

one.

A

hard

disk

drive

was

not

detected

while

the

operating

system

was

being

started.

Reseat

all

hard

disk

drives

and

cables;

then,

run

the

hard

disk

drive

diagnostic

tests

again.

A

hard

disk

drive

passes

the

diagnostic

Fixed

Disk

Test,

but

the

problem

remains.

Run

the

diagnostic

SCSI

Attached

Disk

Test.

Intermittent

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

A

problem

occurs

only

occasionally

and

is

difficult

to

diagnose.

1.

Make

sure

that:

v

All

cables

and

cords

are

connected

securely

to

the

rear

of

the

server

and

attached

devices.

Attention:

In

a

dc

power

environment,

only

trained

service

personnel

other

than

Lenovo

service

technicians

are

authorized

to

connect

or

disconnect

power

to

the

dc

power

supply.

See

the

documentation

that

comes

with

each

dc

power

supply.

v

When

the

server

is

turned

on,

air

is

flowing

from

the

fan

grille.

If

there

is

no

airflow,

the

fans

are

not

working.

This

can

cause

the

server

to

overheat

and

shut

down.

2.

Check

the

system

event/error

log

(see

“Error

Logs”

in

the

Hardware

Maintenance

Manual).

Chapter

7.

Solving

problems

131

Advertising