Lenovo 3797 User Manual

Page 36

Advertising
background image

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

LED

Description

Action

MEM

When

only

the

MEM

LED

is

lit,

a

memory

error

has

occurred.

When

the

MEM

and

CNFG

LEDs

are

lit,

the

memory

configuration

is

not

valid.

1.

Determine

whether

the

CNFG

LED

is

also

lit.

If

it

is,

run

the

memory

test

exerciser

to

isolate

the

problem

(see

Hardware

Maintenance

Manual

for

more

information).

a.

If

the

test

reports

that

a

memory

error

has

occurred,

replace

the

failing

DIMM,

which

is

indicated

by

the

lit

LED

on

the

system

board.

b.

If

the

test

reports

the

memory

configuration

is

invalid,

repopulate

the

DIMMs

to

a

supported

configuration.

2.

If

the

CNFG

LED

is

not

lit,

one

of

the

following

conditions

should

be

present:

v

The

server

did

not

boot

and

a

failing

DIMM

LED

is

lit.

a.

Check

for

a

PFA

log

event

in

the

System

Event

Log

(SEL)

b.

Reseat

the

DIMM.

c.

If

the

problem

remains,

move

the

DIMM

to

a

different

slot.

1)

If

the

DIMM

LED

lights

up

on

the

system

board

that

corresponds

to

this

new

DIMM

socket,

replace

the

DIMM.

2)

If

the

DIMM

LED

lights

up

on

the

system

board

that

corresponds

to

the

original

DIMM

socket,

replace

the

system

board

(trained

service

technician

only).

v

The

server

booted

and

the

failing

DIMM

is

disabled

and

the

LED

is

lit.

a.

If

the

LEDs

are

lit

by

two

DIMMs,

check

the

System

Event

Log

for

PFA

on

one

of

the

DIMMs,

then

replace

that

DIMM.

Otherwise,

replace

both

DIMMs.

b.

If

the

LED

is

lit

by

only

one

DIMM,

replace

that

DIMM.

c.

Re-enable

the

DIMM

sockets

in

the

server

firmware

settings.

NMI

A

nonmaskable

interrupt

has

occurred,

or

the

NMI

button

has

been

pressed.

Check

the

system-event

log

for

information

about

the

error.

CNFG

A

hardware

configuration

error

has

occurred.

(This

LED

is

used

with

the

MEM

and

the

CPU

LEDs.)

20

ThinkServer

RD220

Types

3729,

3779,

3797,

and

3798:

Installation

and

User

Guide