Lenovo 3797 User Manual
Page 36

v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
LED
Description
Action
MEM
When
only
the
MEM
LED
is
lit,
a
memory
error
has
occurred.
When
the
MEM
and
CNFG
LEDs
are
lit,
the
memory
configuration
is
not
valid.
1.
Determine
whether
the
CNFG
LED
is
also
lit.
If
it
is,
run
the
memory
test
exerciser
to
isolate
the
problem
(see
Hardware
Maintenance
Manual
for
more
information).
a.
If
the
test
reports
that
a
memory
error
has
occurred,
replace
the
failing
DIMM,
which
is
indicated
by
the
lit
LED
on
the
system
board.
b.
If
the
test
reports
the
memory
configuration
is
invalid,
repopulate
the
DIMMs
to
a
supported
configuration.
2.
If
the
CNFG
LED
is
not
lit,
one
of
the
following
conditions
should
be
present:
v
The
server
did
not
boot
and
a
failing
DIMM
LED
is
lit.
a.
Check
for
a
PFA
log
event
in
the
System
Event
Log
(SEL)
b.
Reseat
the
DIMM.
c.
If
the
problem
remains,
move
the
DIMM
to
a
different
slot.
1)
If
the
DIMM
LED
lights
up
on
the
system
board
that
corresponds
to
this
new
DIMM
socket,
replace
the
DIMM.
2)
If
the
DIMM
LED
lights
up
on
the
system
board
that
corresponds
to
the
original
DIMM
socket,
replace
the
system
board
(trained
service
technician
only).
v
The
server
booted
and
the
failing
DIMM
is
disabled
and
the
LED
is
lit.
a.
If
the
LEDs
are
lit
by
two
DIMMs,
check
the
System
Event
Log
for
PFA
on
one
of
the
DIMMs,
then
replace
that
DIMM.
Otherwise,
replace
both
DIMMs.
b.
If
the
LED
is
lit
by
only
one
DIMM,
replace
that
DIMM.
c.
Re-enable
the
DIMM
sockets
in
the
server
firmware
settings.
NMI
A
nonmaskable
interrupt
has
occurred,
or
the
NMI
button
has
been
pressed.
Check
the
system-event
log
for
information
about
the
error.
CNFG
A
hardware
configuration
error
has
occurred.
(This
LED
is
used
with
the
MEM
and
the
CPU
LEDs.)
20
ThinkServer
RD220
Types
3729,
3779,
3797,
and
3798:
Installation
and
User
Guide