CARE AND OPERATION

PAGE 15

BLOWER SYSTEM
The Blower System consists of a ON / OFF
rocker switch, a variable speed blower speed
control switch (rheostat) located on the right
side panel, a thermally activated switch (fan
disc) and 4 axial blowers.

When starting a fire, leave the blower system
off until the insert is thoroughly heated (approx.
30 minutes after start up).

The blowers can be operated in one of the fol-
lowing manners:

Auto:
Turn rocker switch to the off position (
O” = off, ““ = on). Turn the rheostat to the on
position by rotating the rheostat dial clockwise
until it clicks. When the insert warms up (110

°

F), the blower will automatically turn on (adjust
rheostat dial to the desired speed setting).
When the insert cools down (90

° F), the blow-

ers will automatically turn off.
Manual: Turn rocker switch to the on ( )
position and adjust rheostat dial to the desired
speed. The blowers will have to be manually
turned off by rotating the rheostat dial counter-
clockwise until it clicks.

BLOWER SPECIFICATIONS
: 115 V, 60 Hz,
two axial blowers - .42 amps each, 125 CFM
each. Blower system has a flexible electrical
cord that must be electrically grounded per lo-
cal codes or NEC, ANSI / NFPA 70-latest edi-
tion. Do not route the power cord under or in
front of the appliance.

Blower System Controls

Located on right side of door at bottom of panel

WIRING DIAGRAM

POWER FLOW DIAGRAM

CAUTION: BURNING THE INSERT AT A HIGH BURN RATE
FOR EXTENDED PERIODS WITHOUT RUNNING THE BLOW-
ERS CAN CAUSE EXCESSIVE TEMPERATURES RESULTING
IN OVERFIRING DAMAGE TO THE APPLIANCE. EXCESSIVE
HEAT WILL CAUSE THE PROPELLERS ON THE BLOWERS TO
MELT. IF THIS OCCURS, REPLACE PROPELLERS AND RE-
VIEW THESE INSTRUCTIONS FOR PROPER OPERATION
(PROPELLER PART / CATALOG #410-25-3. SOME PEOPLE
PREFER METAL PROPELLERS, WHICH ARE AVAILABLE
THROUGH GRAINGER, STOCK #2C953. BE ADVISED THAT
THESE ARE NOISIER THAN STANDARD PLASTIC BLADES).
OVERFIRING DAMAGE IS NOT COVERED UNDER THE 5 YEAR
PRORATED WARRANTY.


WARNING: THIS APPLIANCE IS EQUIPPED WITH A BLOWER
SYSTEM WHICH HAS A FLEXIBLE ELECTRICAL POWER
CORD WITH A THREE-PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY
GROUNDED THREE-PRONG RECEPTACLE PER LOCAL
CODES OR NEC, ANSI / NFPA 70 - LATEST EDITION. DO NOT
CUT OR REMOVE THE GROUNDING PRONG FROM THE
POWER CORD PLUG. DO NOT ROUTE POWER CORD UNDER
OR IN FRONT OF APPLIANCE.