Paxar Sierra Sport2 9460 User Manual

Page 18

Advertising
background image

2-6 System Administrator’s Guide

Sensors

Use this option to view the black mark, die cut, on-demand, and aperture
sensor settings.
To exit, press

F at any time.

1. From the Diagnostics menu, select Printer, Sensors, Black Mark.

Black

Mark

A/D Value = 170

The acceptable range is between 0 and 255 and the A/D values
change as supply moves past the sensors. The count changes by
at least 100 steps when a black mark is under the sensor. If you
do not notice at least a 100-step difference, you may need to call
Service.

2. Press

F to return to the Sensors menu.

3. Select Die Cut.

Die

Cut

A/D Value = 170

The acceptable range is between 0 and 255 and the A/D values
change as supply moves past the sensors. The count changes by
at least 100 steps when die cut labels move through the sensor.
If you do not notice at least a 100-step difference, you may need
to call Service.

4. Press

F to return to the Sensors menu.

Advertising