The requirements of the alarm
signal level are as follows:
Low level: 0 V to 0.8 V
High level: more than 3.3 V

(max. 12 V)

Pulse width: 2 s or more
3 s or less

q Relay output: max. 30 VDC,

1 A or 125 VAC, 0.3 A

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

1

20

RS485 Connection

A 25-pin connector is used to accept and supply control signals.

TERMINAL/CONTROL

Internal block diagram

13

25

1

14

RA

TA

RB

TB

Pin No.

Signal

Operation

Remarks

TA

TB

RA

RB

Terminal input 1

Terminal input 2

Terminal input 3

Terminal input 4

Terminal input 5

Terminal input 6

Terminal input 7

Terminal input 8

+12 V

Grounding

Alarm Output 1 (N.O.)

Alarm Output 1 (N.C.)

Alarm Output 1 (Common)

Alarm Output 2 (N.O.)

Alarm Output 2 (N.C.)

Alarm Output 2 (Common)

Alarm Output 3 (N.O.)

Alarm Output 3 (N.C.)

Alarm Output 3 (Common)

Grounding

Grounding

Sends the alarm signal to external
alarm unit 2.

Sends the alarm signal to external
alarm unit 3.

+12 V voltage output

Sends the alarm signal to external
alarm unit 1.

RS485 camera sending + data

RS485 camera sending – data

RS485 camera receiving + data

RS485 camera receiving – data

When an alarm occurs in channels 1
– 8, the alarm signals are sent to the
recorder through these ports.