Panasonic WJ-RT208 User Manual

Page 40

Advertising
background image

40

Channel Name: Indicates the correlation between the

camera title and serial number. Channel name can
be changed using the provided software.

Cautions: For the [All] operation and functions, refer to the

timer recording explanation.

Notes:

1. "CH Enable" of channel 1 cannot be set at "Off". During

playback in channel 1, it is impossible to set up its
masking area.
Mask Enable:
"On": Used to enable masking area setup. The masked

area will not be displayed and recorded (Black
screen will be recorded.).

"Off": The masking function is not effective.

2. During operation in sequence mode, "CH Enable" can-

not be set up.

3. When the setup value for "Rec. Reserve" exceeds one

day, the screen data for a maximum of "preset number
of days + 4 hours" can be reserved.

4. "Mask Area" can be set up with the procedures speci-

fied below.
Move the cursor to "Set" of "Mask Area" and press the
[SET] button. The masking area setup screen is then
opened.

a) The red cursor in the above diagram indicates the

starting position and the black cursor indicates the
ending position. When the direction button is used,
it is possible to move both the red and black cur-
sors simultaneously throughout the area. It is also
possible to move the black cursor only to adjust the
area size. Determine if you make a control mode
changeover by pressing the [SET] button, moving
the red and black cursors at the same time, or mov-
ing the black cursor only.

b) When Numeral 1 is pressed, the profile of the mask-

ing area is displayed. When 2 is pressed, all the
area is embedded.

3.1.6 Communication setup (COMMUNICA-

TION SETUP)

Network setup (NETWORK SETUP)

Move the cursor to "COMMUNICATION SETUP" on "WJ-
RT208 SETUP MENU" and press the [SET] button.

Move the cursor to "NETWORK SETUP" and press the [SET]
button.

IP Address: IP address given to this unit
Subnet Mask: Subnet mask for this unit
Gateway: Gateway address for this unit
Server Port: Port number of this unit
Protocol: Communication protocol
Alarm Center IP: IP address of the PC on which the

Alarm Center is installed

Alarm Port: Communication port number of the alarm

center, 1024 - 9999
Default: [4000]

Alarm Enable: "On" or "Off"

Default: "Off"

Line Speed: Communication speed of the network card

is set up to match network communications.

Notes:

1. In regard to initial setting and setup enabled range,

refer to "Parameters and initial setup values for the
setup menu."

2. It is necessary to restart the unit after changing the set-

tings.

Mask area

Start position

End position

COMMUNICATION SETUP

NETWORK SETUP

RS485 SETUP

DATA PORT SETUP

OK

NETWORK SETUP

192.168.000.088

IP Address

Cancel

255.255.255.000

Subnet Mask

192.168.000.088

Gateway

2000

Server Port

TCP

Protocol

192.168.000.188

Alarm Center IP

4000

Alarm Port

Off

Alarm Enable

Auto Mode

Line Speed