Paradyne 9128-II User Manual

Page 378

Advertising
background image

D. Technical Specifications

D-6

April

2002

9128-A2-GB20-60

Physical Environment

Operating temperature

Storage temperature

Relative humidity

Shock and vibration

35

°

F to 122

°

F ( 1.7

°

C to 50

°

C)

– 4

°

F to 158

°

F ( –20

°

C to 70

°

C)

5% to 85% ( noncondensing )

Withstands normal shipping and handling

Physical Dimensions

Height

Width

Depth

10.5 inches

(26.7 cm) or 6U

17.2 inches (43.7 cm)

14.3 inches

(36.3 cm)

Weight

Empty access carrier (without power supply)

11 lbs. 6 oz. (5.16 kg)

AC Power Requirements

AC Power Supply

DC Power Supply

90 to 265 VAC, 50/60 Hz

±

3A maximum

– 48 VDC, 6.6 amps, 316 watts

Heat Dissipation (Max.)

227 VAC

– 48 VDC

Fully loaded access carrier

585 Btu per hour maximum

465 Btu per hour maximum

Typical Power Consumption

AC Power Supply

1 power supply installed

2 power supplies installed

DC Power Supply

1 power supply installed

2 power supplies installed

100 VAC 60 Hz 1.7 amps 171 watts
120 VAC 60 Hz 1.03 amps 60 watts
100 VAC 50 Hz 1.15 amps 60 watts
Result: 207 Btu per hour

100 VAC 60 Hz 1.25 amps 64.5 watts
120 VAC 60 Hz 1.5 amps 177 watts
230 VAC 50 Hz 0.9 amps 172 watts
Result: 221 Btu per hour

104 watts at – 48 VDC
Result: 355 Btu per hour

124 watts at – 48 VDC
Result: 423 Btu per hour

Table D-3.

14-Slot 9000 Series Access Carrier Technical Specifications (2 of 2)

Specification

Criteria

Advertising
This manual is related to the following products: