3. Configuration

9128-A2-GB20-60

April 2002

3-17

Setting Up Dial Backup

When configuring units with ISDN backup capability, the following guidelines
apply:

T

Central site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a BRI DBM, change the Automatic Backup Configuration to

Multi_Site_Backup. (A PRI DBM is already configured for multisite
backup.)

— Modify the Link Profile(s) that Automatic Backup Configuration created to

add a phone number.

T

Remote site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a PRI DBM, change the Automatic Backup Configuration to

Single_Site_Backup. (A BRI DBM is already configured for single-site
backup.)

— Modify the HQ_Site Link Profile that Automatic Backup Configuration

created to add a phone number.

— Set the criteria by which automatic backup will take place.

Setting Up the DBM Physical Interface

Procedure

1. Configure the DBM interface.

Main Menu

→

Configuration

→

ISDN

→

Physical

2. Enable the interface, and enter the Service Profile IDs (SPIDs) and local

phone numbers.

3. Save the configuration.

See

Table 3-9, ISDN BRI DBM Physical Interface Options

, or

Table 3-10, ISDN

PRI DBM Physical Interface Options

, for configuration information.