Potterton Solar - Solar Thermal Domestic Hot Water System

25

5.0

Fault finding

5.1

Failures with error message

Some system failure modes can be recognised by the

solar differential temperature controller and will be

indicated by an error message on the controller display.

Refer to the table below for details of possible errors

and suggested measures to rectify.

Error representation on display

Possible reasons

Measures

flashing

• Sensor wire broken

• Check wire

• Sensor defect

• Check sensor resistance, if necessary exchange sensor

flashing

• Short circuit in sensor wire

• Check wire

• Sensor defect

• Check sensor resistance, if necessary exchange sensor

• Error in pump connection

• Check cabling

• Pump defect

• Exchange pump

• Air in the system

• Check the float of the flow meter moves

when the system runs (if visible)

• Connection with flow

• Check wire

meter defect
• Sensor wire broken

• Check wire

• Sensor defect

• Check sensor resistance, if necessary exchange sensor

!
!

!

+

Circulation error: no flow

Additionally at energy

productivity measurement:

flashing