0 fault finding – Baxi Potterton Solar User Manual

Page 26

Advertising
background image

Potterton Solar - Solar Thermal Domestic Hot Water System

26

Resistance table PT1000.

The correct function of temperature sensors can be

checked on the basis of the following temperature

resistance table with a resistance measuring instrument:

5.0

Fault finding

Temperature in ºC

Resistance in Ohm

-30

882

-20

921

-10

960

0

1000

10

1039

20

1077

30

1116

40

1155

50

1194

60

1232

70

1271

80

1309

90

1347

100

1385

120

1461

140

1535

200

1758

YES

No display at solar differential

temperature controller

Controller fault

Replace controller

Is the 230/240V~ power

supply switched on

YES

Has thermal cutout

on cylinder operated

(unvented systems only)

NO

NO

Is internal

fuse operational

YES

NO

Replace internal fuse

Check wiring and rectify

Reset thermal cutout.

Investigate cause of operation

and rectify

Is the 230/240V~

power supply at the controller

terminal block

Switch on power supply

Is the 230/240V~ power

supply correctly wired

YES

NO

YES

NO

Correct any wiring faults

Advertising