Pentair INTELLIFLO VS-3050 User Manual

Page 25

Advertising
background image

17

IntelliFlo VS-3050 Installation and User’s Guide

Section 3

User Maintenance

The following information describes how to service and maintain the IntelliFlo VS-3050 pump.

Pump Strainer Basket

The strainer, sometimes referred to as the “Hair and Lint Pot,” is in front of the of the pump. Inside there is
a basket which must be kept clean of leaves and debris at all times. View the basket through the top see
through lid to inspect for leaves and debris.

Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint
pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and possibly the heater.

WARNING —

DO NOT open the strainer pot if pump fails to prime or if pump has been operating without
water in the strainer pot. Pumps operated in these circumstances may experience a build up
of vapor pressure and may contain scalding hot water. Opening the pump may cause serious
personal injury. In order to avoid the possibility of personal injury, make sure the suction and
discharge valves are open and that the strainer pot is cool to the touch, then open with
extreme caution.

CAUTION —

To prevent damage to the pump and filter and for proper operation of the system, clean
pump strainer and skimmer baskets regularly.

Pump Strainer Basket Service

If the IntelliFlo pump is installed below the water level of the pool,
close the return and suction lines before opening the hair and lint pot
on the pump.

1. Press the Stop button to stop the pump and switch off the pump

at the circuit breaker.

2. Disconnect the communication cable from the IntelliFlo pump.

3. Relieve pressure in the system.

4. Turn the clamp and lid in a counterclockwise direction until it

stops.

5. Remove the clamp and lid.

6. Remove the basket and put the debris into the trash and rinse out

the basket. If the basket is cracked, replace the basket.

7. Replace the basket and fill the pump pot and volute with water

up to the inlet port.

8. Clean the cover, o-ring, and sealing surface of the pump pot. Grease

the o-ring with Teflon or silicone lubricant.

9. Reinstall the lid by placing the clamp and the lid on the pot.