Paradyne T1 T1 Access Mux 926x User Manual
Page 257

SNMP Traps
C-5
9161-A2-GH30-30
April 1998
The tests that support these traps and conditions that define enterpriseTestStart
and enterpriseTestStop for each interface:
Interface
enterpriseTestStart/Stop
Variable-Bindings
For These Tests
Network and DSX-1
T1 Interfaces
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
All
H
dsx1SendCode
(RFC 1406)
H
Remote Line Loopback
H
Send 511 pattern
H
Send 3 in 24
H
Send QRSS
H
dsx1LoopbackConfig
(RFC 1406)
H
Line Loopback
H
Payload Loopback
H
devDS1TestType
(devDS1Config.mib)
H
Repeater Loopback
H
Send All Zeroes
H
Send All Ones
H
Send 1-in-8
H
Send 63
H
Send 2047
H
Send 2
15
-1
H
Send 2
20
-1
H
Send user-defined pattern
H
All Monitor patterns
Synchronous
Data Ports
H
ifIndex (RFC 1573)
H
ifAdminStatus
(RFC 1573)
H
ifOperStatus (RFC 1573)
H
i
fType (RFC 1573)
H
devSyncPortTestType
(devDataPortConfig.mib)
H
DTE Loopback
H
DTE Payload Loopback
H
Data Channel Loopback
H
Send V.54 Loopback
H
Send FT1 Loopback
H
Send pattern tests
H
Monitor pattern tests