Technical specifications, Appendix f – Paradyne T1 T1 Access Mux 926x User Manual

Page 301

Advertising
background image

F-1

9161-A2-GH30-30

April 1998

Technical Specifications

F

Specification

Criteria

Network Access Module (NAM)

Approvals

FCC Part 15

FCC Part 68

Industry Canada

UL

CSA – Safety

Class A digital device.

Refer to the equipment’s label for the
Registration Number.

Refer to the equipment’s label for the
Certification Number.

Refer to the equipment’s label for the UL listing.

Refer to the equipment’s label for CSA safety
information.

Weight

T1 NAM

T1 I/O Card

1 lb. 2 oz. ( .510 kg )

6 oz. (.170 kg)

Physical Environment

Operating temperature

Storage temperature

Relative humidity

Shock and vibration

35

°

F to 122

°

F ( 1.7

°

C to 50

°

C )

– 4

°

F to 158

°

F (– 20

°

C to 70

°

C )

5% to 85% ( noncondensing )

Withstands normal shipping and handling

Power Consumption

9.4 watts, 0.78 amps input current at 12 volts

Network 1/2 T1 Interface

Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation

RJ48C
CA81A using adapter cable
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable