2 front panel, Figure 4-7 appearance of the rpu front panel – Panasonic 324566-A User Manual

Page 71

Advertising
background image

Nortel Secure Router 8012
Hardware Description

4 Boards

Issue 5.3 (6 April 2009)

Nortel Networks Inc.

4-13

z

supports the active and standby switchover

z

supports hot swapping

z

supports the hot and cool backup

In addition, the RPU provides two Gigabit Ethernet (GE) ports. It supports the exclusion of
the optical function and the electrical function on the GE port; that is, you cannot use the
optical function and the electrical function on the GE port at the same time..

4.2.2 Front panel

Figure 4-7 shows the appearance of the panel. Table 4-5 describes the components.

Figure 4-7 Appearance of the RPU front panel

PW

R1

PW

R2

Table 4-5 Description of the components on the front panel of an RPU

Name

Silkscreen

Description

SYS

The system running LED, including the fan,
power supply, and NPU warnings. Constant ON
means the CPU received a warning.

ALM (red)

NPU

The NPU failure LED. Constant ON means the
NPU failed.

RUN

The system running LED. Blinking means the
CPU works normally. Constant ON or OFF
means the CPU failed.

RPU (green)

MST

The standby state LED. On means that the board
is the master RPU.