RT-HIC-8FE

Table 4-15 describes the indicators of the10/100Base-TX Ethernet electrical interface module.

Table 4-15 Description of indicators of the 10/100Base-TX Ethernet electrical interface module

LED

Description

LINK

OFF means the link is not connected and ON means the link is connected.

ACT

OFF means no data is being transmitted or received on the interface and
blinking means data is being transmitted or received. A high frequency of
blinking means a large data flow.

4.4.3 Interface attributes

Table 4-16 shows the attributes of the 10/100Base-TX Ethernet electrical interface.

Table 4-16 Attributes of the 10/100Base-TX Ethernet electrical interface module

Attribute

Description

Connector type

RJ45

Cable type

Standard Ethernet cable

Transmission distance

100 m (with Category 5 twisted pair cable)

Operating mode

Full duplex/Half duplex
10M/100 Mbit/s autonegotiation

Compliant standard

IEEE 802.3u

Supported frame format

Ethernet_II
Ethernet_SNAP

Supported network protocol

IP

4.5 100Base-FX Ethernet optical interface module

The 100Base-FX Ethernet optical interface modules of the Secure Router 8012 are as follows: