• Genlock Adjustment

To use the camera in external sync mode, phase adjust-
ment is necessary to match the phases with those of the
other units and camera. No G/L adjustment is necessary in
case of no genlock.

• Horizontal Phase Adjustment

q Set G/L PHASE ON/OFF Switch of the multi hybrid con-

trol panel to the ON position.

Note:

When G/L PHASE ON/OFF Switch of the multi

hybrid control panel is set to the ON position, the
sync phase of the camera changes to the settings
of G/L PHASE H Control, G/L PHASE Coarse
Switch, and G/L PHASE SC Control. Unless G/L
phase adjustment is necessary, do not set G/L
PHASE ON/OFF Switch to the ON position.

w Observe the waveforms of the G/L signal input (black

burst signal ) and video signal output on a dual chan-
nel oscilloscope, and turn the G/L horizontal phase
control to match the horizontal phase as shown in the
next page.