Co line connection, Wire specification, Wire – Panasonic KX-T206E User Manual

Page 12: Diameter of conductor, Diameter with coating, Connection, The wire specifications are as follows, Solid wire, Co 2 co 1

Advertising
background image

12

CO Line Connection

Wire Specification

The wire specifications are as follows:

Wire

Solid wire

Diameter of conductor

ш 0.4 – ш 0.65mm

Diameter with coating

ш 0.66 – ш 1.05mm

Connection

Use a 4-pin plug (included) to connect CO lines.
A single plug is able to connect two CO lines. Use twisted pair cable.

1. Lift the transparent part.
2. Insert the required telephone wires into the holes of the plug.

Then press the transparent part back into the black part.

Note: Do not strip the wires.

Insert the wires all the way into the plug.

GROUND

SYSTEM

EXTN.

5

EXTN.

3

EXTN.

1

CO 2
CO 1

EXTN.

6

EXTN.

4

EXTN.

2

DPH

DOOR

OPENER

A

A

B

B

CO 2
CO 1

CO 2

CO 1

To Modular Jacks from
the Central Office

A

B

CO 2

A

B

CO 1

CO 2

CO 1

Note
• You can use cable holders to fix the wires.

Advertising