24

C2629M-A (6/07)

Different types of devices may require alternative cable wiring schemes. Wiring schemes commonly used by Pelco products include straight and
rollover types. Refer to the documentation included with your PTZ device to ensure that cables and connectors are wired appropriately. Figure 13
illustrates straight and rollover cable wiring schemes.

PIN

1
2
3
4
5
6
7
8

PIN

1
2
3
4
5
6
7
8

PIN

1
2
3
4
5
6
7
8

PIN

1
2
3
4
5
6
7
8

RJ-45

STRAIGHT CABLE

ROLLOVER CABLE

RJ-45

RJ-45

RJ-45

Figure 13. Cable Wiring Schemes

ALARM INPUT INSTALLATION

The DX8100 has either 8 or 16 dry contact alarm inputs, depending on your system’s configuration. Each input is programmed to function as
either a normally open or normally closed circuit.

To wire an alarm input:

1. Insert the green terminal blocks into the alarm sockets on the back panel of the recorder.

2. Connect one wire from the source device to one of the sensor input terminals 1 through 16.

3. Connect a second wire from the source device to a GND terminal.

4. Refer to the DX8100 Operation/Programming manual for information on how to program the alarm inputs.

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN9

IN10

IN11

IN12

IN13

IN14

IN15

IN16

OUT16

OUT15

OUT14

OUT13

OUT12

OUT11

OUT10

OUT9

OUT9

OUT8

OUT7

OUT6

OUT5

OUT4

OUT3

OUT2

OUT1

ALARM INPUTS

RELAY OUTPUTS

1 2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16

1 2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16

9 10 11 12 13 14 15 16

CRT

ALARM

OUTPUT 1

GND

Figure 14. Alarm Terminal Installation