VIX AE SERVO DRIVE USER GUIDE

54

AB, AI and AO Description

AB controls the dead band and AO the offset of the differential analogue speed/torque
control input. See Differential Analogue Input in the Electrical Installation section.

AM Description

Use output 4 (X5 pin 15) to output an analogue DC voltage between +10V and –10V to
represent the velocity or torque being generated by the drive, depending upon the setting of
system variable AM. Setting AM to 2 generates a bipolar triangular waveform with a time
period of 1 second.

BR Description

This sets the Baud rate of serial communications. Enter the required Baud rate directly, for
example aW(BR,19200) to set the rate to 19200. You will need to save this setting and then
reset the drive (Z command) or cycle the power before the change will take effect.

CL and PC Description

See Motor Related System Variables in the Electrical Installation section.