Parker Products ViX250AE User Manual

Page 67

Advertising
background image

VIX AE SERVO DRIVE USER GUIDE

60

Bit Number

Stop

Type

DF Information

1

Composite fault (anything that causes a drive
fault)

2

K

T

+/-15V supply rail

3

K

R

Motor HV under-voltage trip point reached

4

K

R

Motor HV over-voltage trip point reached

5

C

R

V I/O under-voltage trip point reached

6

C

R

V I/O over-voltage trip point reached

7

K

T

Encoder/Auxiliary 5V under voltage trip

8

K

T

Impending power loss
(24V – logic supply)

9

K

T

Commutation Fault

10

K

T

Resolver fault

11

C

R

Motor over temperature

12

C

R

Ambient over temperature

13

C

R

Drive over temperature

14

K

T

Incompatible firmware version

15

K

T

Unrecognised power stage

16

K

T

Controller diagnostic failure

17

K

R

Output stage over current

18

C

R

Output driver over current

19

C

R

Tracking limit exceeded while in motion is a
latched fault

20

K

R

Velocity exceeded (unstable gains/motor spin-
off)

21

C

R

Energise input not set – check energise input
and state of ES variable

22-24

Reserved

25

K

T

Watchdog 1

26

K

T

Watchdog 2

27

K

T

Watchdog 3

Table 4-5. Drive Fault Bit Description

Key:

C: Performs controlled stop
K: Performs motion kill – quick stop. Possible instant de-energise depending on fault source
R: Recoverable without power cycle
T: Terminal (requires power cycle or repair before drive will energise/operate again)

Drive Fault Byte Reporting

In exactly the same way as the status variable, the drive fault status can be reported a byte
at a time, using DFn within a read command.