4. CONTROL OF VIX DRIVES 67

Torque Mode Commands

For the ViX drive issue the following commands:

1MT

;Mode Torque

1W(ES,0)

;Energise input active level

1GAINS(0,0,0,0,0)

;Zero all gains

1SV

;Save settings

A valid MOTOR command is required.

All GAINS need to be 0.0

For the 6K4 issue the following commands:

AXSDEF1111

All axes are steppers

ERES8000,8000,8000,8000

Should match ViX motor resolution

DRFLVL1111

Drive fault active level

DRFEN1

Enable drive fault detection

LH0,0,0,0

Disable limits (optional)

TGAIN

Read all gains

SGP

Set proportional gain

SVG

Set velocity gain

A
V
D
GO1

Execute move