32 about connectors, Using the alarm/control connector, Pin assignments – Panasonic WJ-ND400 User Manual

Page 32

Advertising
background image

32

About Connectors

You can use emergency recording and auto adjustment time functions when alarm equipment like a buzzer or indicator which is mounted
externally.

Create the connector by referring to the pin assignments.

The pin assignments are different for other Network Disk Recorders. Connect using the following chart.

Using the Alarm/Control connector

Pin Assignments

14

25

13

1

ALARM/CONTROL

Pin

Number

Name

Description of Operation

Remarks

1

Alarm input 8

Event action will be performed according to the
settings.

Non-voltage make contact input 5V
pull-up 150 k

Ω

2

Alarm input 9

3

Alarm input 10

4

Alarm input 11

5

Alarm input 12

6

Alarm input 13

7

Alarm input 14

8

Alarm input 15

9

Alarm input 16

10

Network error output

Signal output upon detection of a broken Ethernet
link.
Signal output upon DHCP IP address expiration.

Open collector output 24 V DC max.,
100 mA

11

Alarm reset input

Canceling the alarm display

Non-voltage make contact input 5V
pull-up 150 k

Ω

12

Emergency recording input

Starting emergency recording signal input

13

Signal ground

14

Signal ground

15

Available disk space
warning output

Signal output for available disk space warning of
the recording/copy area

Open collector output 24 V DC max.,
100 mA

16

HDD error output

Signal output upon detection of a HDD error

17

Camera error output

Signal output upon detection of a camera error

18

Error output

Signal output upon detection of a unit error

19

Power outage recovery
completion output

Signal output upon completion of outage
processing

High (+5 V - +12 V, 6.3 mA max.)

20

Time adjustment input/
output

The time of this unit is adjusted to the preset time
according to the signal input. This signal output is
then generated for the setting time of this unit.
Time of all other units is adjusted to the setting
time of this unit.

52 k

Ω 5 V pull-up, Output current –100

mA/Non-voltage make contact input

21

Alarm output

Alarm signal output at an event occurrence

Open collector output 24 V DC max.,
100 mA

ND400_Basic.book 32 ページ 2008年4月8日 火曜日 午後3時59分

Advertising