Error messages – Printronix SL5000e User Manual

Page 47

Advertising
background image

Selecting The Tools

47

Error Messages

The RFID encoder can detect a number of errors. When one of
these errors occurs, the RFID encoder alerts the printer to perform
the currently selected error action (see “Error Handling” on
page 18)
and display the appropriate error message on the control
panel’s LCD (see Table 2).

Table 2. Control Panel Error Messages

Error Message

Explanation

Solution

RFID MAX RETRY
Check System

Error Handling = Overstrike in
the RFID CONTROL menu,
and the Label Retry count has
been exhausted.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 48.

RFID Comm Err
Check Cable

RFID error: communication
cannot be established with
the RFID encoder. Reader
will be set to Disable in the
RFID CONTROL menu and
the previous port settings
restored.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 48.

RFID TAG FAILED
Check Media

Error Handling = Stop in the
RFID CONTROL menu, and
the RFID encoder could not
read the RFID tag.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 48.

Advertising