NI 9481 Operating Instructions and Specifications
18
ni.com
Shock and Vibration
To meet these specifications, you must panel mount the system and
either affix ferrules to the ends of the terminal wires or use the
NI 9932 backshell kit to protect the connections.
Operating vibration,
sinusoidal (IEC 60068-2-6) .............. 5 g, 40 to 500 Hz; 0.062 in.
double amplitude,
10 to 40 Hz
Environmental
National Instruments C Series modules are intended for indoor use
only but may be used outdoors if installed in a suitable enclosure.
Refer to the manual for the chassis you are using for more
information about meeting these specifications.
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 70 °C
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... –40 to 85 °C
Ingress protection.............................. IP 40