Specifications / 109

P0881594 Issue 01

MICS-XC Norstar-Companion Installer Guide

External antenna assembly (For the US)

AC supply voltage

120 V

AC supply frequency

60 Hz

Secondary voltage

12 V

Secondary current

800 mA

Operating temperature

5

°C

to 40

°C (

+32°F to +120°F)

Relative humidity

5 to 85% (condensation may occur)

Height

10 cm (4 in.)

Width

10 cm (4 in.)

Depth

6 cm (2 in.)

Part no.

antenna: NTAE50AA (A0637293)

Frequency range

1.92 to 1.93 GHz

Peak power rating

+13.5 dBm

Peak antenna gain

between –1.2 and 1.5 dBi

Polarization

nominally vertical

Input impedance

50

nominal

Voltage standing wave ratio

better than 1.5:1

Extension cable loss

below 4.5 dB

Lightning surge arrestor circuit
current

3 kA

Lightning surge arrestor
waveform pulse

8

/

20

µS

Lightning surge arrestor
repetition

20 times

p0881594.book Page 109 Tuesday, August 25, 1998 3:59 PM