FP-PWM-520 and cFP-PWM-520

To install the cFP-PWM-520, refer to Figure 2 and complete the
following steps:

1. Align the captive screws on the cFP-PWM-520 with the screw

holes on the backplane. The alignment keys on the
cFP-PWM-520 prevent backward insertion.

2. Press firmly to seat the cFP-PWM-520 on the backplane.

3. Using a number 2 Phillips screwdriver with a shank of at least

64 mm (2.5 in.) length, tighten the captive screws to 1.1 N

⋅ m

(10 lb

⋅ in.) of torque. The nylon coating on the screws prevents

them from loosening.