Change GPIB Device Templates

For older NI-488.2 applications, you might need to modify one of the
device templates to find a given GPIB instrument by name, for example,

ibfind("fluke45")

. Older applications still use

ibfind

instead of the

preferred

ibdev

to obtain a device handle. In new applications, avoid using

ibfind

to obtain device handles and use

ibdev

instead. You can use

ibdev

to dynamically configure your GPIB device handle.

ibdev

also

eliminates unneccessary device name requirements.

If you must modify a device template, run the GPIB Configuration utility.

1.

Start Measurement & Automation Explorer as described in the

Starting Measurement & Automation Explorer

section.

2.

Select Help»Help Topics»NI-488.2 to view the NI-488.2 Help.

3.

Search for the topic named How do I change a GPIB Device Template?
and click the link to open the GPIB Configuration utility.

4.

Double-click the device template you want to modify, such as DEV1.

5.

Rename the template as described in your application documentation.

6.

Click the OK button twice to save your changes and exit.

Enable/Disable NI-488.2 DOS Support

Note

NI-488.2 DOS support is not available on Windows Vista or later operating systems.

To enable or disable NI-488.2 DOS support, complete the following steps:

1.

Start Measurement & Automation Explorer as described in the

Starting Measurement & Automation Explorer

section.

2.

Click on your GPIB interface and select Tools»NI-488.2»
DOS Support...
from the Explorer menu.

3.

Enable or disable DOS support in the NI-488.2 Settings dialog box
and click OK.

4.

If you are prompted to do so, restart your system.