NI 9234 Operating Instructions and Specifications

22

ni.com

IEPE compliance voltage.................. 19 V max

If you are using an IEPE sensor, use the following equation to make
sure your configuration meets the IEPE compliance voltage range.

(V

common-mode

+ V

bias

± V

full-scale

) must be 0 to 19

Overvoltage protection (with respect to chassis ground)

For a signal source connected
to AI+ and AI– ........................... ±30 V
For a low-impedance source
connected to AI+ and AI– .......... –6 to 30 V

Input delay ........................................ 38.4/ f

s

+ 3.2

μs

where

V

common-mode

is the common-mode voltage applied

to the NI 9234

V

bias

is the bias voltage of the IEPE sensor

V

full-scale

is the full-scale voltage of the IEPE sensor