Figure 2-3. clearing the cmos contents – National Instruments PXI NI PXI-8105 User Manual

Page 26

Advertising
background image

Chapter 2

Installation and Configuration

NI PXI-8105 User Manual

2-12

ni.com

Complete the following steps to clear the CMOS contents:

1.

Power off the chassis.

2.

Remove the controller from the chassis.

3.

Move the jumper on W7 from pins 1–2 to pins 2–3, as shown in
Figure 2-3.

4.

Wait one second. Move the jumper back to pins 1–2.

5.

Reinstall the controller in the chassis.

Caution

Do not leave the jumper on pins 2–3. Doing so decreases battery life. In addition,

leaving the jumper on the pins prevents the controller from booting.

Figure 2-3. Clearing the CMOS Contents

1

Normal Operation (Default)

2

Clear CMOS Contents

3

Pin 1

1

2

3