Shock and vibration, Safety, Electromagnetic compatibility – National Instruments PXI NI PXI-8105 User Manual

Page 58

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-3

NI PXI-8105 User Manual

Shock and Vibration

Operational shock .................................. 30 g peak, half-sine, 11 ms pulse

(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random vibration

Operating ........................................ 5 to 500 Hz, 0.3 g

rms

(with solid-state hard drive)

Nonoperating .................................. 5 to 500 Hz, 2.4 g

rms

(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)

Safety

This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1

CAN/CSA-C22.2 No. 61010-1

Note

For UL and other safety certifications, refer to the product label or to

ni.com/certification

, search by model number or product line, and click the

appropriate link in the Certification column.

Electromagnetic Compatibility

Emissions ............................................... EN 55011 Class A at 10 m

FCC Part 15A above 1 GHz

Immunity ................................................ EN 61326:1997 + A2:2001,

Table 1

EMC ....................................................... CE, C-Tick, and FCC Part 15

(Class A) compliant

Note

For full EMC compliance, operate this device with shielded cabling.