Appendix a specifications, Analog input, Input characteristics – National Instruments SC-2040 User Manual

Page 44: Transfer characteristics

Advertising
background image

© National Instruments Corporation

A-1

SC-2040 User Manual

Appendix A
Specifications

This appendix lists the specifications for the SC-2040. These are typical at 25

°

C unless otherwise stated. The

operating temperature range is 0

°

to 50

°

C.

Analog Input

Input Characteristics

Number of channels

8 differential

Input signal ranges

Board Gain

(Hardware

Selectable)

Board Range

Max Output Range

±

10 V

1

±

10 V

10

±

1 V

100

±

100 mV

200

±

50 mV

300

±

33.3 mV

500

±

20 mV

600

±

16.67 mV

700

±

14.29 mV

800

±

12.5 mV

Input coupling

DC

Max working voltage

(signal + common mode)

Average of 2 inputs should remain within

±

7 V of ground

Overvoltage protection

±

30 V powered on,

±

15 V powered off

Inputs protected

ACH<0..7>

Transfer Characteristics

Offset error

Pregain error after calibration

±

100

µ

V max

Postgain error after calibration

±

2 mV max

Gain error and nonlinearity

Gain

(DIP-switch-

selectable)

Max

Gain Error

Max

Gain Tempco

Max

Nonlinearity

1

±

0.05%

±

25 ppm/

°

C

±

0.01%

10

±

0.1%

±

25 ppm/

°

C

±

0.01%

100

±

0.2%

±

45 ppm/

°

C

±

0.02%

200

±

0.4%

±

60 ppm/

°

C

±

0.02%

300

-0.3%,

±

0.6%

±

80 ppm/

°

C

±

0.03%

500

±

1.0%

±

100 ppm/

°

C

±

0.04%

600

-0.2%,

±

1.5%

±

120 ppm/

°

C

±

0.05%

700

-0.1%,

±

2.0%

±

150 ppm/

°

C

±

0.06%

800

-0.3%,

±

3.0%

±

200 ppm/

°

C

±

0.07%

Advertising