National Instruments NI 9264 User Manual

Page 13

Advertising
background image

© National Instruments Corp.

13

NI 9264 Operating Instructions and Specifications

Power-down voltage ......................... 0 V

1

Output impedance............................. 2.0

Ω

Accuracy

Stability

Gain drift .................................... 6 ppm/°C
Offset drift .................................. 80

μV/°C

1

The power-down voltage peaks at 1.7 V, then exponentially discharges to 0 V in
200 ms. You can add a load to reduce peak voltage.

Measurement Conditions

Percent of

Reading

(Gain Error)

Percent of

Range

*

(Offset Error)

Calibrated, max (–40 to 70 °C)

0.15%

0.15%

Calibrated, typ (25 °C)

0.05%

0.05%

Uncalibrated, max (–40 to 70 °C)

0.6%

1.0%

Uncalibrated, typ (25 °C)

0.2%

0.25%

*

Range equals 10.5 V