From here, the Administrator’s Name, User ID and Password can be changed. Also, Local users may be
added by filling out a new row and selecting the add button. Once Local users have been added, a user can
be removed by selecting the delete button and can be updated by changing the information and selecting the
update button.

Callback Security Options:

1) Administrator:

If the Callback Security option is enabled and Admin specified is selected, then enter your fixed

callback telephone number in the Callback # window. If the Callback Security option is enabled and User
Specified
is selected, you do not enter a telephone number in the Callback # window. You enter the
callback telephone number during the dial-in process.

2) Remote user:

If you are going to enable the Callback Security option, click on the Callback down arrow and

choose the callback method. A fixed phone number is Admin specified or a variable phone number is User
specified
. For example, if a traveling sales person needs to be called back at their current location, they will
provide the callback telephone number during the dial-in process.

If the Callback Security option is enabled and Admin specified is selected, then enter their fixed

callback telephone number in the Callback # window. If the Callback Security option is enabled and User
specified
is selected, you do not enter a telephone in the callback # window. The remote user enters the
callback number during the dial-in process.

Note: The first row is for the “Administrator” function. No matter what values are used for the Name,

User ID and Password fields, the first row will apply to the person doing the Administrator function
for the 102RAS. The Administrator is the party privileged to configure the 102RAS.


Call Log


The Call Log screen displays the parameters you can set for the Call Log entries and displays a call log
entry for each call.


The Log Parameters define the threshold number of entries and the number of entries retained in the log
history. Both Auto Log Threshold and Log History can be set to a maximum of 20 entries by filling in the
field and clicking on Save Changes. The log can be E-Mailed to the Administrator address by clicking on
Send Log Now and the Log can be deleted by clicking on Delete Log.


The Call Log summarizes each call and the Details button displays an in-depth look at the call from the
individual initiating the call, when the call was connected, duration of the call, transmit and receive baud
rates, to authentication status.