Using Long Cables

The inductance of the cabling that connects the NI 9478, the loads,
and the external supply stores up energy when a channel is on and
passing current through the cables. Each time a channel is turned
off, the energy stored in the cables is released as flyback voltage
and dissipates as heat in the NI 9478. The total power dissipated in
the module increases with higher switching frequencies, higher
currents, and longer cable lengths. The cable length is the total
distance from the digital output pin of the NI 9478 channel,
through the load, through the external power supply, and back
to the COM pin, as shown in Figure 4.