Cabling Requirements for NI 9852

This section deals with cabling specifications, termination
resistors, cable lengths, and the number of CAN nodes that can
exist in a system.

Cable Specifications

Cables should meet the physical medium requirements specified in
ISO 11898, shown in Table 3. Belden cable (3084A) meets all of
those requirements, and should be suitable for most applications.

Table 3. Specifications for Characteristics of a CAN_H and CAN_L Pair of

Wires

Characteristic

Value

Length-related resistance

90 m

Ω/m nominal

Length-related
capacitance:
CAN_L and ground,
CAN_H and ground,
CAN_L and CAN_H

30 pF/m nominal