Number of CAN Nodes

The maximum number of nodes depends on the electrical
characteristics of the nodes on the network. If all of the nodes meet
the requirements of Low-Speed/Fault-Tolerant CAN, up to
32 nodes may be connected to the bus.

NI 9852 Hardware Overview

The NI 9852 has two full-featured, independent CAN ports that are
isolated from each other, and from the other modules in the system.
Each port of the NI 9852 has a Philips SJA1000 CAN controller
that is CAN 2.0B-compatible and fully supports both 11-bit
and 29-bit identifiers. Each port also has a Philips TJA1054A
Low-Speed/Fault-Tolerant CAN that is fully compatible with the
ISO 11898 standard and supports baud rates up to 125 Kbps.